PURETEC HYBRID FACTORY MAINTENANCE KIT
Puretec HR-G12R10 Factory Service Kit – Suits Hybrid G12 & R10
The Puretec HR-G12R10 is the genuine manufacturer-listed maintenance kit for compatible Puretec Hybrid G12 and Hybrid R10 whole-house filtration and ultraviolet systems.
The kit combines the three replacement filter cartridges with the key UV service components required for scheduled maintenance: PL05MP1, CB05MP1, PX01MP1, RL6 UV lamp, RQS6 quartz sleeve, food-grade lubricant and two O-rings.
Rather than replacing only one filter stage, the HR-G12R10 provides the principal consumable components specified by Puretec for a major G12 or R10 maintenance service.
Quick answer:
the Puretec HR-G12R10 suits Hybrid G12 and Hybrid R10 systems. It contains three 4.5" × 10" MaxiPlus cartridges, an RL6 46W UV lamp, an RQS6 quartz sleeve, food-grade lubricant and two O-rings. Puretec's Hybrid maintenance guide specifies cartridge replacement every 6 months, annual UV lamp replacement and regular quartz-sleeve inspection.
KIT AT A GLANCE
Puretec HR-G12R10 Key Details
3 Cartridges
PL05MP1 + CB05MP1 + PX01MP1
```
RL6
46W UV Lamp
RQS6
Quartz Sleeve
2 O-Rings
Plus Food-Grade Lubricant
```
WHAT'S INCLUDED
Factory Maintenance Kit Contents
PL05MP1
5 micron, 4.5" × 10" washable pleated polyester sediment cartridge.
```
CB05MP1
5 micron, 4.5" × 10" bonded activated-carbon block cartridge for chlorine, unwanted taste, odour and sediment reduction.
PX01MP1
1 micron, 4.5" × 10" graded polyspun polypropylene sediment cartridge.
RL6 UV Lamp
46W high-output ultraviolet replacement lamp specified for compatible Hybrid G, R and P Series systems.
RQS6 Quartz Sleeve
Replacement quartz sleeve used around the UV lamp inside the applicable Puretec UV chamber.
Service Components
Food-grade lubricant and two O-rings are included in the manufacturer-listed HR-G12R10 kit.
```
THREE FILTRATION STAGES + UV
Designed for the Full G12 & R10 Treatment Sequence
Compatible Hybrid G12 and R10 systems use three cartridge stages before ultraviolet treatment.
Stage 1 provides washable 5 micron sediment filtration, Stage 2 adds activated-carbon treatment for chlorine, unwanted taste and odour, and Stage 3 provides finer 1 micron sediment filtration.
Water then passes through the UV chamber, where the RL6 lamp and RQS6 quartz sleeve form part of the system's microbiological treatment stage.
STAGE 1
PL05MP1 5 Micron Washable Sediment Cartridge
The PL05MP1 is installed nearest the water inlet as the first cartridge stage.
Puretec manufactures it from reusable non-woven polyester media pleated around a polypropylene support core, providing a large filtration surface area for suspended sediment.
5 Micron
Provides nominal 5 micron sediment filtration.
```
4.5" × 10"
Uses Puretec's 10-inch MaxiPlus cartridge format.
90 L/min
Puretec lists the individual PL05MP1 cartridge at up to 90 litres per minute.
Washable
Puretec specifies the pleated polyester media as washable and reusable where appropriate.
Sediment
Designed to reduce dirt, rust, sand, silt and similar suspended particulate material.
Pre-Filtration
Reduces particulate loading before the carbon and fine-sediment stages.
```
STAGE 2
CB05MP1 5 Micron Carbon Block Cartridge
The CB05MP1 is the second cartridge stage in both the Hybrid G12 and Hybrid R10.
It is manufactured from bonded activated carbon and is specified by Puretec for reduction of chlorine, unwanted taste, odour and sediment.
5 Micron
Nominal 5 micron bonded carbon-block filtration.
```
4.5" × 10"
Uses Puretec's 10-inch MaxiPlus carbon cartridge format.
Activated Carbon
Provides the principal chlorine, unwanted taste and odour treatment stage.
Sediment
The carbon block also contributes to particulate reduction within its nominal filtration rating.
Bonded Construction
Puretec specifies bonded activated carbon rather than a loose granular carbon bed.
No Loose Carbon Bed
The bonded construction is designed to avoid the normal release of loose carbon fines associated with granular media.
```
STAGE 3
PX01MP1 1 Micron Fine Sediment Cartridge
The PX01MP1 is installed as the third cartridge stage before ultraviolet treatment.
Puretec manufactures the PX Series from virgin polypropylene using graded-density polyspun construction, allowing sediment to be captured throughout the depth of the filtration media.
1 Micron
Provides fine nominal sediment filtration before the UV chamber.
```
4.5" × 10"
Uses Puretec's 10-inch MaxiPlus format.
75 L/min
Puretec lists the individual PX01MP1 cartridge at up to 75 litres per minute.
```
UV COMPONENT
RL6 46W High-Output UV Lamp
The HR-G12R10 includes one genuine Puretec RL6 46W high-output UV lamp.
The RL6 is specifically listed by Puretec for compatible Hybrid G, R and P Series systems, including the Hybrid G12 and R10.
Puretec specifies annual UV lamp replacement.
The lamp has a rated service life of 365 days, and the applicable Hybrid controller includes a lamp-life timer that is reset after lamp replacement.
QUARTZ SLEEVE
RQS6 Replacement Quartz Sleeve
The RQS6 is a quartz sleeve, not a filter cartridge.
It forms the clear barrier surrounding the UV lamp inside the stainless-steel UV chamber. UV light must pass through this sleeve before reaching the water.
Puretec recommends inspecting the quartz sleeve approximately every 3 months, depending on source-water quality, because deposits on the sleeve can reduce UV transmission.
The sleeve can be cleaned with the appropriate Puretec sleeve cleaner where required, or replaced if damaged or unable to be restored to a suitably clear condition.
COMPATIBILITY
Which Systems Does HR-G12R10 Suit?
Puretec Hybrid G12
The HR-G12R10 matches the manufacturer-listed PL05MP1, CB05MP1, PX01MP1, RL6 and RQS6 service components used in the Hybrid G12.
```
Puretec Hybrid R10
The same HR-G12R10 kit is also the manufacturer-listed maintenance kit for the Hybrid R10 indoor reversible-bracket system.
```
Do not order by appearance alone.
Other Puretec Hybrid models use different cartridge sizes or cartridge combinations. Confirm the exact model before ordering.
HYBRID G12
Service Components for Existing Hybrid G12 Systems
The Hybrid G12 is now listed by Puretec as a discontinued complete system, but Puretec continues to list the HR-G12R10 as the maintenance kit for existing G12 installations.
The G12 uses the following replacement sequence:
- Stage 1 – PL05MP1
- Stage 2 – CB05MP1
- Stage 3 – PX01MP1
- UV lamp – RL6
- Quartz sleeve – RQS6
- 1" BSP [25 mm] system connection
HYBRID R10
Service Components for Hybrid R10 Systems
The Hybrid R10 uses the same three filtration cartridges, RL6 UV lamp and RQS6 quartz sleeve.
The R10 is designed for protected indoor installation and uses a reversible mounting arrangement that allows the system to be configured according to the installation direction.
- Stage 1 – PL05MP1
- Stage 2 – CB05MP1
- Stage 3 – PX01MP1
- UV lamp – RL6
- Quartz sleeve – RQS6
- 1" BSP [25 mm] system connection
G12 VS R10
Same Maintenance Kit, Different System Configuration
| Feature |
Hybrid G12 |
Hybrid R10 |
| Maintenance Kit |
HR-G12R10 |
HR-G12R10 |
| Stage 1 |
PL05MP1 |
PL05MP1 |
| Stage 2 |
CB05MP1 |
CB05MP1 |
| Stage 3 |
PX01MP1 |
PX01MP1 |
| UV Lamp |
RL6 |
RL6 |
| Quartz Sleeve |
RQS6 |
RQS6 |
| Connection |
1" BSP [25 mm] |
1" BSP [25 mm] |
| Installation Style |
Weather-covered G Series configuration |
Protected indoor R Series configuration |
KIT SPECIFICATIONS
Puretec HR-G12R10 Technical Details
| Component |
Specification |
| Kit Model |
HR-G12R10 |
| Compatibility |
Puretec Hybrid G12 and Hybrid R10 |
| Stage 1 Cartridge |
PL05MP1 – 5 micron, 4.5" × 10" washable pleated sediment |
| Stage 2 Cartridge |
CB05MP1 – 5 micron, 4.5" × 10" bonded activated carbon |
| Stage 3 Cartridge |
PX01MP1 – 1 micron, 4.5" × 10" graded polyspun sediment |
| UV Lamp |
RL6 – 46W high-output UV replacement lamp |
| Quartz Sleeve |
RQS6 |
| Lubricant |
Food-grade lubricant included |
| O-Rings |
2 pieces included |
| Cartridge Service Interval |
Every 6 months |
| UV Lamp Service Interval |
Annually |
| Quartz Sleeve Inspection |
Approximately every 3 months depending on source-water quality |
MAINTENANCE SCHEDULE
Not Every Component Uses the Same Service Interval
The original page's generic 6–12 month replacement statement does not accurately describe every component in the HR-G12R10.
Filter Cartridges
Puretec's Hybrid G/R maintenance guide specifies replacement of the filtration cartridges every 6 months.
```
RL6 UV Lamp
The UV lamp must be replaced annually, with a rated lamp life of 365 days.
RQS6 Quartz Sleeve
Inspect approximately every 3 months depending on water quality and clean or replace as required.
```
SERVICE PROCESS
What Is Involved in a Hybrid G12 or R10 Service?
Servicing a Hybrid G12 or R10 involves both the filtration housings and the ultraviolet treatment assembly.
- Confirm the installed system is a Hybrid G12 or Hybrid R10
- Disconnect electrical power before UV servicing
- Turn off the incoming water supply
- Relieve pressure from the filtration system
- Allow UV components to cool before handling
- Remove PL05MP1, CB05MP1 and PX01MP1
- Clean the filter bowls with soap and warm water
- Rinse filter bowls thoroughly
- Inspect housing O-rings and sealing surfaces
- Use the supplied food-grade lubricant where required
- Install PL05MP1 in stage one
- Install CB05MP1 in stage two
- Install PX01MP1 in stage three
- Replace the RL6 UV lamp
- Inspect, clean or replace the RQS6 quartz sleeve as required
- Restore water gradually and check the system for leaks
- Flush cartridges for the applicable period
- Restore power and reset the UV lamp-life timer
CARTRIDGE REPLACEMENT
Correct Cartridge Order Matters
Puretec identifies the cartridge nearest the incoming water supply as Stage 1.
1. PL05MP1
Washable 5 micron pleated sediment cartridge nearest the water inlet.
```
2. CB05MP1
5 micron bonded activated-carbon cartridge in the middle filtration position.
3. PX01MP1
1 micron graded polyspun sediment cartridge immediately before UV treatment.
```
Do not rearrange the cartridge sequence.
The three cartridges perform different functions and should be installed in the positions specified by Puretec.
FLUSHING AFTER SERVICE
Recommission the System After Cartridge Replacement
Puretec's Hybrid maintenance procedure instructs users to restore the water supply gradually with a downstream tap open so trapped air can escape.
The system should then be flushed for approximately 1–2 minutes and checked for leaks before being returned to normal operation.
Puretec also recommends flushing for 1–2 minutes after periods of non-use longer than two weeks. After very long periods of non-use, cartridge replacement may be required depending on condition.
UV SERVICE CARE
Important Lamp & Quartz Sleeve Handling
The UV section requires additional care beyond a standard filter-cartridge service.
Always disconnect power before working on the UV assembly.
Puretec also instructs users to isolate the water supply, release water pressure and allow the UV components to cool before servicing.
Avoid touching the glass surface of the UV lamp unnecessarily, as fingerprints and marks can interfere with UV transmission. The quartz sleeve should also be handled carefully because it is glass and can be damaged during removal or installation.
WHAT IS NOT INCLUDED
Some Maintenance Products & Repairs Remain Separate
The HR-G12R10 includes the three cartridges, RL6 lamp, RQS6 sleeve, food-grade lubricant and two O-rings.
Separate products such as Puretec quartz-sleeve cleaner and filter-housing cleaner should not be described as included unless they are separately supplied with your order.
Existing system faults are separate from scheduled maintenance.
Damaged housings, UV controllers, electrical components, pumps, valves, pipework or other worn parts can require additional components or labour.
BEFORE ORDERING
Check These Details First
- Your installed system is a Puretec Hybrid G12 or R10
- Stage one requires PL05MP1
- Stage two requires CB05MP1
- Stage three requires PX01MP1
- Your system uses an RL6 UV lamp
- Your UV chamber uses an RQS6 quartz sleeve
- You require the full maintenance kit rather than cartridges only
- The system is accessible for both filter and UV servicing
DIY OR PROFESSIONAL SERVICE
Can the HR-G12R10 Be Installed Yourself?
Puretec publishes a maintenance procedure for compatible Hybrid systems, but this service involves both pressurised water filtration components and mains-powered ultraviolet equipment.
The water and electrical power must be safely isolated, the housings must be correctly resealed and the UV lamp and quartz sleeve must be handled without damaging the glass components.
Professional servicing may be appropriate where you are not experienced with Hybrid UV maintenance.
Leaking housings, electrical faults, cracked quartz sleeves, damaged O-rings, seized filter bowls, pumps or associated plumbing can require additional work.
ORDERING OPTIONS
Choose How You Want to Order
Supply Only
Order the genuine Puretec HR-G12R10 for delivery to supported Australian locations where you have confirmed your Hybrid system model.
```
Full Factory Kit
Receive the three cartridges, RL6 lamp, RQS6 quartz sleeve, food-grade lubricant and two O-rings in one maintenance package.
Professional Service Option
Professional Hybrid filtration and UV servicing may be available in eligible Brisbane and Gold Coast service areas.
```
COMMON QUESTIONS
Questions About the Puretec HR-G12R10 Factory Service Kit
What Systems Does the HR-G12R10 Suit?
Puretec specifies the kit for Hybrid G12 and Hybrid R10 systems.
Does It Still Suit a Hybrid G12?
Yes. Although the complete Hybrid G12 is now listed as discontinued, Puretec continues to list HR-G12R10 as its maintenance kit.
What Cartridges Are Included?
The kit includes PL05MP1, CB05MP1 and PX01MP1.
What Order Do the Cartridges Go In?
PL05MP1 is stage one, CB05MP1 is stage two and PX01MP1 is stage three.
Is a UV Lamp Included?
Yes. The kit includes one genuine RL6 46W high-output UV lamp.
Is a Quartz Sleeve Included?
Yes. The kit contains one RQS6 replacement quartz sleeve.
Is the RQS6 a Filter Cartridge?
No. RQS6 is the quartz glass sleeve used around the UV lamp inside the ultraviolet chamber.
Are O-Rings Included?
Yes. Puretec lists two O-rings as included.
Is Food-Grade Lubricant Included?
Yes. Food-grade lubricant forms part of the manufacturer-listed kit contents.
How Often Should the Cartridges Be Replaced?
Puretec's Hybrid G/R maintenance guide specifies replacement every 6 months.
How Often Should the UV Lamp Be Replaced?
Puretec specifies annual replacement of the RL6 lamp.
How Often Should the Quartz Sleeve Be Checked?
Puretec recommends inspection approximately every 3 months, depending on source-water quality.
Does the Kit Include Quartz-Sleeve Cleaner?
No separate quartz-sleeve cleaner is listed as part of the HR-G12R10 kit contents.
Does the Kit Include Filter-Housing Cleaner?
No. Filter-housing sanitiser or cleaner is a separate maintenance product unless specifically added to the order.
Can I Use This Kit in a Hybrid G13 or R11?
No. Puretec lists a separate HR-G13R11P maintenance kit for Hybrid G13, R11 and compatible P Series systems.
Can Installed Today Service the System?
Professional Hybrid cartridge and UV maintenance may be available in eligible Brisbane and Gold Coast service areas where the system is accessible and in serviceable condition.
WHY INSTALLED TODAY
Order the Correct Puretec Hybrid Maintenance Kit
Supply First
Purchase the genuine Puretec HR-G12R10 without adding installation where you already have your own maintenance arrangement.
```
Clearly Defined Contents
The listing identifies each cartridge, UV lamp, quartz sleeve and supplied service item rather than describing the kit as a vague universal maintenance pack.
Installation Capability
If you prefer professional servicing, Installed Today may also be able to carry out the filtration and UV maintenance in selected local service areas.
```
FINAL CHECK
Is the Puretec HR-G12R10 the Right Kit for Your Hybrid System?
The Puretec HR-G12R10 Factory Service Kit is the manufacturer-listed maintenance kit for Puretec Hybrid G12 and Hybrid R10 systems.
It contains PL05MP1, CB05MP1, PX01MP1, RL6 46W UV lamp, RQS6 quartz sleeve, food-grade lubricant and two O-rings, covering the main filtration and ultraviolet service components specified for these systems.
Before ordering, confirm that your installed system is a Hybrid G12 or R10. Puretec specifies cartridge replacement every 6 months, annual UV lamp replacement and quartz-sleeve inspection approximately every 3 months depending on source-water quality. Always isolate both water and electrical power before servicing the UV assembly and check the complete system for leaks after recommissioning.