PURETEC HYBRID FACTORY MAINTENANCE KIT
Puretec HR-G13R11P Factory Service Kit
The Puretec HR-G13R11P is a genuine factory maintenance kit designed for all Puretec Hybrid P Series systems, Hybrid G13 and Hybrid R11.
Rather than supplying only replacement filter cartridges, this kit combines the major filtration and ultraviolet service components used in these compatible Hybrid systems. It includes three 20-inch MaxiPlus cartridges, a replacement UV lamp, a replacement quartz sleeve, food-grade lubricant and two O-rings.
For systems that have reached their scheduled maintenance period, the HR-G13R11P provides the manufacturer-specified components needed to renew the main cartridge filtration stages and service the applicable UV assembly.
Quick answer:
the HR-G13R11P is Puretec's factory maintenance kit for all Hybrid P Series systems plus Hybrid G13 and R11. It includes PL05MP2, CB05MP2, PX01MP2, RL6 UV lamp, RQS6 quartz sleeve, food-grade lubricant and 2 O-rings. Cartridge intervals depend on water quality and usage, while Puretec specifies annual replacement of the UV lamp.
KIT AT A GLANCE
Puretec HR-G13R11P Key Details
3 Cartridges
PL05MP2 + CB05MP2 + PX01MP2
```
RL6
46W UV Lamp
RQS6
Quartz Sleeve
2 O-Rings
Plus Food-Grade Lubricant
```
WHAT'S INCLUDED
Factory Service Kit Contents
PL05MP2
5 micron, 4.5" × 20" washable pleated polyester sediment cartridge.
```
CB05MP2
5 micron, 4.5" × 20" bonded activated-carbon block cartridge for sediment, chlorine, unwanted taste and odour reduction.
PX01MP2
1 micron, 4.5" × 20" graded polyspun polypropylene sediment cartridge for fine particulate filtration.
RL6 UV Lamp
46W high-output replacement UV lamp specified for compatible Hybrid G, R and P Series systems.
RQS6 Quartz Sleeve
Replacement quartz sleeve used around the UV lamp inside the compatible Hybrid UV chamber.
Service Items
Food-grade lubricant and two O-rings are included as part of the factory maintenance kit.
```
THREE-STAGE FILTRATION + UV
Restores the Main Hybrid Filtration & UV Service Components
Compatible Hybrid P, G13 and R11 systems use a three-cartridge filtration sequence followed by ultraviolet treatment.
Stage 1 uses washable pleated sediment filtration, Stage 2 uses activated-carbon treatment, and Stage 3 provides fine 1 micron sediment filtration before the water passes through the UV chamber.
The HR-G13R11P kit supplies replacement components for each of these filtration stages together with the UV lamp and quartz sleeve.
STAGE 1
PL05MP2 5 Micron Washable Sediment Cartridge
The PL05MP2 is the first filtration stage used in compatible Hybrid P, G13 and R11 configurations.
It is manufactured from reusable non-woven polyester media pleated around a polypropylene support core, creating a large surface area for capturing sediment before water reaches the downstream filtration stages.
5 Micron
Provides nominal 5 micron sediment filtration.
```
4.5" × 20"
Uses Puretec's large 20-inch MaxiPlus cartridge format.
180 L/min
Puretec lists the individual PL05MP2 cartridge at up to 180 litres per minute.
Washable
Puretec specifies the pleated polyester media as washable and reusable where appropriate.
Sediment
Designed to reduce dirt, rust, sand, silt and suspended particulate material.
Pre-Filtration
Reduces sediment loading before water reaches the carbon and fine-sediment stages.
```
STAGE 2
CB05MP2 5 Micron Carbon Block Cartridge
The CB05MP2 is a bonded activated-carbon block cartridge used as the second filtration stage.
Puretec specifies the CB05MP2 for reduction of chlorine, unwanted taste, odour and sediment. The bonded carbon construction is designed to avoid the normal release of loose carbon fines during operation.
5 Micron
Nominal 5 micron carbon block filtration.
```
4.5" × 20"
Large MaxiPlus carbon cartridge format.
48 L/min
Puretec lists the individual CB05MP2 cartridge at up to 48 litres per minute.
Chlorine
Provides activated-carbon treatment for chlorine reduction.
Taste & Odour
Designed to reduce unwanted taste and odour.
Bonded Carbon
Uses activated-carbon block construction rather than a loose granular carbon bed.
```
STAGE 3
PX01MP2 1 Micron Fine Sediment Cartridge
The PX01MP2 is the third cartridge stage specified in compatible systems using this maintenance kit.
It is manufactured from virgin polypropylene using graded-density polyspun construction, providing nominal filtration down to 1 micron.
1 Micron
Provides fine nominal sediment filtration before the UV treatment stage.
```
4.5" × 20"
Uses Puretec's 20-inch MaxiPlus format.
152 L/min
Puretec lists the individual PX01MP2 cartridge at up to 152 litres per minute.
```
UV LAMP
Puretec RL6 46W High-Output UV Lamp
The kit includes one genuine Puretec RL6 46W high-output UV replacement lamp.
The RL6 is specified for compatible Hybrid G, R and P Series ultraviolet systems. It forms the active lamp component inside the UV chamber after the cartridge filtration stages.
Puretec recommends replacing the UV lamp annually.
The Hybrid lamp timer is designed around a 12-month lamp-service period. UV lamp output declines with operating time even when the lamp continues to illuminate.
QUARTZ SLEEVE
Puretec RQS6 Replacement Quartz Sleeve
The RQS6 is a quartz sleeve, not a filter cartridge.
It forms the clear barrier between the UV lamp and the water flowing through the stainless-steel UV chamber. Keeping this sleeve clean is important because deposits on the quartz can reduce transmission of UV light into the water.
Puretec's Hybrid maintenance guidance recommends inspecting the quartz sleeve regularly, approximately every 3 months depending on source-water quality. The sleeve can be cleaned where required and should be replaced if damaged or if it cannot be restored to a suitably clear condition.
COMPATIBILITY
Which Puretec Systems Use HR-G13R11P?
Puretec currently lists the HR-G13R11P maintenance kit as suitable for:
- All Puretec Hybrid P Series systems
- Puretec Hybrid G13
- Puretec Hybrid R11
- Compatible HybridPlus configurations using the same replacement components
Puretec has marketed the Hybrid P family across models including P1, P3, P6, P9 and P12. The exact installed system model should still be checked before ordering.
HYBRID G13
Replacement Components Match the Puretec Hybrid G13
Puretec specifies the following replacement sequence for the Hybrid G13:
Stage 1
PL05MP2 washable 5 micron pleated sediment cartridge.
```
Stage 2
CB05MP2 5 micron bonded carbon block cartridge.
Stage 3
PX01MP2 1 micron graded polyspun sediment cartridge.
UV Lamp
RL6 46W high-output lamp.
Quartz Sleeve
RQS6 replacement quartz sleeve.
Service Kit
HR-G13R11P combines these components into one factory maintenance package.
```
HYBRID P SERIES
Factory Maintenance Kit for the HybridPlus P Range
Puretec's Hybrid P systems use the same principal cartridge and UV replacement components supplied in the HR-G13R11P kit:
- PL05MP2 first-stage sediment cartridge
- CB05MP2 second-stage carbon cartridge
- PX01MP2 third-stage fine sediment cartridge
- RL6 ultraviolet replacement lamp
- RQS6 quartz sleeve
This is why Puretec identifies HR-G13R11P as suitable for all Hybrid P Series models rather than for only one P configuration.
KIT SPECIFICATIONS
Puretec HR-G13R11P Technical Details
| Component |
Specification |
| Kit Model |
HR-G13R11P |
| Compatibility |
All Hybrid P Series, Hybrid G13 and Hybrid R11 |
| Stage 1 Cartridge |
PL05MP2 – 5 micron, 4.5" × 20" washable pleated sediment |
| Stage 2 Cartridge |
CB05MP2 – 5 micron, 4.5" × 20" bonded carbon block |
| Stage 3 Cartridge |
PX01MP2 – 1 micron, 4.5" × 20" graded polyspun sediment |
| UV Lamp |
RL6 – 46W high-output replacement lamp |
| Quartz Sleeve |
RQS6 |
| Lubricant |
Food-grade lubricant included |
| O-Rings |
2 pieces included |
| Cartridge Interval |
Typically 6–12 months depending on water quality and usage |
| UV Lamp Interval |
Replace annually |
CARTRIDGE PERFORMANCE
Individual Cartridge Specifications
| Feature |
PL05MP2 |
CB05MP2 |
PX01MP2 |
| Stage |
1 |
2 |
3 |
| Micron Rating |
5 micron |
5 micron |
1 micron |
| Size |
4.5" × 20" |
4.5" × 20" |
4.5" × 20" |
| Media |
Pleated polyester |
Bonded activated carbon |
Polyspun polypropylene |
| Listed Individual Flow |
180 L/min |
48 L/min |
152 L/min |
| Main Function |
Sediment pre-filtration |
Chlorine, taste, odour and sediment treatment |
Fine sediment filtration |
Individual cartridge flow rates are not complete Hybrid system flow ratings. Complete-system performance depends on the particular Hybrid model, UV dose requirement, pump, pipework, water pressure and other installation conditions.
MAINTENANCE TIMING
Not Every Component Uses the Same Service Interval
The HR-G13R11P combines components with different maintenance requirements.
Filter Cartridges
Puretec specifies cartridge replacement approximately every 6–12 months, depending on water quality and usage.
```
RL6 UV Lamp
Puretec recommends UV lamp replacement every 12 months.
RQS6 Quartz Sleeve
Inspect regularly, approximately every 3 months depending on water quality, and clean or replace as required.
```
The complete maintenance kit is therefore particularly useful for a major scheduled Hybrid service, while cartridge servicing may be required earlier where sediment loading or water use is high.
WHY MAINTENANCE VARIES
What Can Bring Service Forward?
Sediment Loading
Higher dirt, rust, silt or organic particulate levels can load the filtration cartridges more quickly.
```
Total Water Use
Properties using greater volumes of water may reach practical cartridge capacity sooner.
Source-Water Quality
Changes in tank, rainwater or backup-water conditions can affect both cartridge loading and quartz-sleeve fouling.
Carbon Treatment Demand
Chlorine and unwanted taste-and-odour treatment demand influences the service life of the CB05MP2.
Quartz Deposits
Mineral or other deposits on the RQS6 sleeve can reduce UV transmission and require cleaning.
Reduced Flow
A noticeable reduction in flow can indicate that one or more cartridges have become loaded.
```
SERVICE PROCESS
What Is Involved in a Hybrid Factory Service?
Servicing a compatible Hybrid system involves both water-filtration and ultraviolet components.
- Confirm the installed system is compatible with HR-G13R11P
- Turn off electrical power to the Hybrid UV system
- Turn off the incoming water supply
- Relieve system water pressure
- Allow UV components to cool before servicing
- Remove the existing PL05MP2, CB05MP2 and PX01MP2 cartridges
- Clean applicable filter housings as instructed
- Inspect housing sealing surfaces
- Replace applicable supplied O-rings where required by the service procedure
- Use the supplied food-grade lubricant as applicable
- Install cartridges in the correct stage order
- Remove and replace the RL6 UV lamp carefully
- Inspect, clean or replace the RQS6 quartz sleeve as required
- Reassemble the UV chamber correctly
- Restore water gradually and check for leaks
- Restore electrical power and reset the applicable UV lamp timer
UV SERVICE CARE
Important Lamp & Quartz Sleeve Handling
UV servicing requires additional care beyond a normal cartridge replacement.
Disconnect power before working on the UV system.
Puretec instructs users to isolate both power and water and allow UV components to cool before servicing.
The UV lamp and quartz sleeve should be handled carefully. Marks, fingerprints or deposits on the glass surfaces can interfere with UV transmission.
If the quartz sleeve is removed for inspection, it should be cleaned correctly before reassembly or replaced if damaged or unable to be restored to a clear condition.
BEFORE ORDERING
Check These Details First
- Your system is a compatible Hybrid P Series model, G13 or R11
- Stage one requires PL05MP2
- Stage two requires CB05MP2
- Stage three requires PX01MP2
- The UV system uses an RL6 lamp
- The UV chamber uses an RQS6 quartz sleeve
- You require the full factory maintenance kit rather than cartridges only
- The system is accessible for cartridge and UV servicing
WHAT THE KIT DOES NOT AUTOMATICALLY INCLUDE
Additional Cleaning or Repair Parts May Still Be Required
The HR-G13R11P includes the manufacturer-listed cartridges, lamp, quartz sleeve, lubricant and two O-rings.
Puretec also offers separate maintenance products such as UV sleeve cleaner and filter-housing cleaner. These should not be treated as included unless specifically supplied with your order.
Existing faults are separate from scheduled consumable maintenance.
Damaged filter housings, UV controllers, electrical components, pumps, valves, pipework or other system parts can require additional diagnosis, parts or labour.
DIY OR PROFESSIONAL SERVICE
Can the HR-G13R11P Be Installed Yourself?
Puretec provides maintenance instructions and video guidance for compatible Hybrid systems, but this kit involves more than a basic filter-cartridge change because it also includes the ultraviolet lamp and quartz sleeve.
The system must be safely isolated from both water and electrical power, the filtration housings must be correctly resealed, and the UV assembly must be dismantled and reassembled without damaging the glass components.
Professional servicing may be appropriate where you are not experienced with Hybrid UV maintenance.
Existing leaks, damaged seals, electrical faults, cracked quartz sleeves, seized filter bowls or pump-related issues can require work outside the normal factory-kit service.
ORDERING OPTIONS
Choose How You Want to Order
Supply Only
Order the genuine Puretec HR-G13R11P factory maintenance kit for delivery to supported Australian locations where you have confirmed system compatibility.
```
Full Maintenance Kit
Receive the three filtration cartridges plus RL6 lamp, RQS6 quartz sleeve, food-grade lubricant and two O-rings in one manufacturer-specified package.
Professional Service Option
Professional Hybrid cartridge and UV servicing may be available in eligible Brisbane and Gold Coast service areas.
```
COMMON QUESTIONS
Questions About the Puretec HR-G13R11P Factory Service Kit
What Systems Does HR-G13R11P Suit?
Puretec specifies the kit for all Hybrid P Series systems, Hybrid G13 and Hybrid R11.
What Filter Cartridges Are Included?
The kit contains PL05MP2, CB05MP2 and PX01MP2.
Is a UV Lamp Included?
Yes. The kit includes one genuine Puretec RL6 46W high-output UV lamp.
Is the Quartz Sleeve Included?
Yes. One RQS6 replacement quartz sleeve is included.
Are O-Rings Included?
Yes. Puretec lists 2 O-rings as included in the HR-G13R11P.
Is Lubricant Included?
Yes. Food-grade lubricant is included in the factory kit.
What Is the First Cartridge?
PL05MP2, a washable 5 micron pleated polyester sediment cartridge.
What Is the Second Cartridge?
CB05MP2, a 5 micron bonded activated-carbon block cartridge for chlorine, unwanted taste, odour and sediment reduction.
What Is the Third Cartridge?
PX01MP2, a 1 micron graded polyspun polypropylene sediment cartridge.
How Often Are the Cartridges Replaced?
Puretec specifies approximately 6–12 months, depending on water quality and usage.
How Often Is the RL6 UV Lamp Replaced?
Puretec recommends UV lamp replacement annually.
How Often Should the Quartz Sleeve Be Checked?
Puretec recommends inspecting the quartz sleeve regularly, approximately every 3 months depending on source-water quality.
Is the RQS6 Another Filter Cartridge?
No. The RQS6 is the quartz glass sleeve surrounding the UV lamp inside the UV chamber.
Does the Kit Include UV Sleeve Cleaner?
Puretec's HR-G13R11P contents list does not include separate SC1000 UV sleeve cleaner. That is a separate maintenance product.
Can I Use the Kit in a Hybrid E13?
Puretec lists a separate current maintenance kit for Hybrid E13, E13AMC and I13 systems. Order the maintenance kit specified for the exact Hybrid model.
Can Installed Today Service the System?
Professional Hybrid cartridge and UV maintenance may be available in eligible Brisbane and Gold Coast service areas where the system is accessible and in serviceable condition.
WHY INSTALLED TODAY
Order the Correct Puretec Hybrid Factory Kit
Supply First
Purchase the genuine HR-G13R11P factory kit without adding installation where you already have your own maintenance arrangement.
```
Correct Kit Contents
The product is clearly identified with all three cartridges, RL6 lamp, RQS6 sleeve, lubricant and two O-rings rather than a vague generic service-kit description.
Installation Capability
If you prefer professional servicing, Installed Today may also be able to carry out the filtration and UV maintenance in selected local service areas.
```
FINAL CHECK
Is the Puretec HR-G13R11P the Right Maintenance Kit for Your Hybrid System?
The Puretec HR-G13R11P Factory Service Kit is the manufacturer-listed maintenance kit for all Hybrid P Series systems, Hybrid G13 and Hybrid R11.
It contains PL05MP2, CB05MP2, PX01MP2, RL6 46W UV lamp, RQS6 quartz sleeve, food-grade lubricant and 2 O-rings, covering the main filtration and UV consumable components used during scheduled Hybrid maintenance.
Before ordering, confirm the model of your installed Hybrid system. Follow Puretec's applicable cartridge maintenance interval of approximately 6–12 months, replace the UV lamp annually, inspect the quartz sleeve regularly and ensure both the water supply and electrical power are correctly isolated before servicing the UV assembly.