PURETEC SEDIMENT FILTER CARTRIDGE
Puretec PX05MP1 5 Micron Polyspun Sediment Cartridge
The Puretec PX05MP1 is a MaxiPlus sediment filter cartridge designed to remove particulate material such as sediment, rust, sand, silt and algae from water before it reaches downstream filtration stages, plumbing fixtures or other water-treatment components.
Puretec uses a graded polyspun construction that provides depth filtration throughout the cartridge rather than relying only on the outer surface.
The PX05MP1 has a nominal 5 micron rating, uses the larger 4.5 inch × 10 inch MaxiPlus format and is specified by Puretec for a flow rate of up to 76 litres per minute.
Quick answer:
the Puretec PX05MP1 is a genuine 5 micron, 4.5" × 10" graded polyspun sediment cartridge for compatible MaxiPlus filter housings and Puretec systems that specify this cartridge. It is designed to capture sediment, rust, sand, silt and algae while providing high-flow particulate pre-filtration.
PRODUCT AT A GLANCE
Puretec PX05MP1 Key Specifications
5 Micron
Nominal Rating
```
4.5" × 10"
MaxiPlus Size
76 L/min
Listed Maximum Flow
Polyspun
Graded Sediment Media
```
WHAT IT DOES
What Does the Puretec PX05MP1 Filter?
The PX05MP1 is a sediment cartridge. Its purpose is to physically capture suspended particulate material as water moves through the graded polyspun media.
Sediment & Dirt
Captures particulate material that can contribute to cloudy water, sediment accumulation and loading of downstream filters.
```
Sand, Silt & Rust
Puretec specifies the PX Series for removal of sand, silt and rust from the water supply.
Algae
Puretec also identifies algae removal among the applications for its PX Series sediment cartridges.
```
HOW IT WORKS
Graded-Density Depth Filtration
The PX05MP1 is constructed as a graded polyspun sediment cartridge.
Rather than trapping all material on one flat surface, the depth-filter design allows particulate material to be captured through the thickness of the filtration media.
This makes the cartridge suited to sediment pre-filtration applications where dirt-loading capacity and water flow are important.
Outer Filtration Layers
Larger particulate material can be captured toward the outer portion of the cartridge media.
```
Deeper Filtration
Finer particles continue further into the graded media before being captured.
Depth Loading
Using the depth of the cartridge media allows particulate loading to be distributed through more of the filter structure.
```
5 MICRON SEDIMENT FILTRATION
Designed for Fine Particulate Pre-Filtration
The PX05MP1 has a nominal 5 micron rating, making it a relatively fine sediment filtration stage for compatible water-treatment systems.
Its primary role is particulate filtration. It should not be treated as a carbon cartridge or as a replacement for filtration stages specifically designed for chlorine, taste, odour or dissolved contaminant reduction.
Where a multi-stage system uses both sediment and carbon cartridges, the PX05MP1 will commonly perform the sediment pre-filtration role before the downstream carbon stage.
CARTRIDGE SIZE
Puretec MaxiPlus 4.5" × 10" Format
The PX05MP1 uses Puretec's larger MaxiPlus 4.5 inch × 10 inch cartridge format.
This is different from standard slimline 2.5-inch cartridges, so the physical cartridge format must be checked before ordering.
Check the cartridge size before purchase.
A 10-inch cartridge is not automatically interchangeable with every 10-inch filter. Confirm that the housing or filtration system is designed to accept the 4.5-inch diameter MaxiPlus format and specifically supports the PX05MP1 or an equivalent approved cartridge.
FLOW PERFORMANCE
High-Flow Sediment Filtration
Puretec lists the PX05MP1 with a flow range up to 76 litres per minute in applicable system specifications.
Actual flow through an installed filtration system is also affected by the filter housing, other cartridges, pipework, incoming pressure, water conditions and the complete system's rated flow.
Where the PX05MP1 is used in a multi-stage system, the lowest-flow component can determine the practical maximum flow of the complete filtration setup.
SPECIFICATIONS
Puretec PX05MP1 Technical Specifications
| Specification |
Puretec PX05MP1 |
| Product Type |
Polyspun sediment replacement cartridge |
| Cartridge Series |
Puretec PX Series |
| Format |
MaxiPlus 4.5" × 10" |
| Nominal Micron Rating |
5 micron |
| Media Type |
Graded polyspun sediment media |
| Targeted Material |
Sediment, rust, sand, silt and algae |
| Listed Flow |
Up to 76 L/min |
| Listed Temperature Range |
0–60°C in applicable Puretec system specifications |
| Listed Pressure Range |
100–900 kPa in applicable Puretec system specifications |
SYSTEM COMPATIBILITY
Which Systems Use the PX05MP1?
The PX05MP1 is used in compatible Puretec filtration systems designed around the MaxiPlus 4.5" × 10" cartridge format.
Puretec specifically lists the PX05MP1 as the sediment-stage replacement cartridge for systems including the WH2-30 and WH2-35.
Puretec WH2-30
The PX05MP1 is specified as the first-stage sediment cartridge in the WH2-30 whole-house filtration system.
```
Puretec WH2-35
Puretec's replacement guide also lists the PX05MP1 as the sediment cartridge for the WH2-35.
Other Compatible MaxiPlus Housings
Other systems may use the cartridge where their manufacturer or system specification calls for the same cartridge format and filtration specification.
```
MULTI-STAGE FILTRATION
Why Use a Sediment Cartridge Before a Carbon Filter?
In dual-stage systems, sediment filtration is commonly positioned before the carbon stage.
The PX05MP1 captures particulate material before it reaches the downstream cartridge, helping the next filtration stage focus on its intended treatment role.
For example, Puretec specifies the PX05MP1 as stage one and the CB10MP1 carbon block as stage two in the WH2-30 system.
WHEN TO REPLACE
How Often Should the PX05MP1 Be Replaced?
Puretec's whole-house maintenance guidance gives a general cartridge replacement interval of approximately 6–12 months, depending on water quality and usage.
Sediment cartridge life can vary considerably because the PX05MP1 physically captures particles from the incoming supply.
- Applicable 6–12 month service interval has been reached
- Water flow has noticeably reduced
- Pressure drop through the filtration system has increased
- Cartridge has become heavily loaded with sediment
- Incoming water has experienced unusually high sediment loading
- Previous replacement date is unknown
WHY SERVICE LIFE VARIES
What Affects Sediment Cartridge Life?
Incoming Water Quality
Water containing more suspended sediment will load the cartridge faster than a cleaner incoming supply.
```
Water Usage
A property using a greater volume of water will pass more particulate material through the filtration system.
Upstream Conditions
Changes in mains supply, tank water conditions, plumbing work or sediment disturbance can alter how quickly the cartridge loads.
```
CARTRIDGE REPLACEMENT
What Is Involved in Replacing a PX05MP1?
The exact replacement process depends on the filter housing or Puretec filtration system in which the cartridge is installed.
- Turn off the incoming water supply
- Relieve pressure from the filtration system
- Open the appropriate filter housing
- Remove the used sediment cartridge
- Clean the filter bowl
- Inspect the housing O-ring and sealing surfaces
- Insert the new PX05MP1 correctly
- Reassemble the filter housing
- Restore water pressure gradually
- Check the housing and connections for leaks
O-RING MAINTENANCE
Check the Filter Housing Seal During Replacement
Whenever a cartridge housing is opened, the filter bowl O-ring and sealing surfaces should be checked before reassembly.
Puretec's whole-house maintenance guidance recommends checking O-rings for damage and replacing them where required. Puretec also provides a general recommendation to replace applicable housing O-rings approximately every 3–5 years.
Where lubrication is required, Puretec specifies a light coating of suitable food-grade silicone lubricant or similar product.
DIY OR PROFESSIONAL SERVICE
Can You Replace the PX05MP1 Yourself?
Cartridge replacement can be completed by the owner where the filtration system is designed for user servicing and the water supply can be safely isolated and depressurised.
Correct housing reassembly is important because the O-ring and filter bowl need to reseal correctly before the system is repressurised.
Use professional servicing if you are unsure.
If the filtration housing is difficult to isolate, difficult to open, leaking or showing damaged seals or fittings, professional cartridge replacement is a practical option.
PROFESSIONAL REPLACEMENT
Professional Cartridge Replacement Option
Professional replacement may be available in eligible Installed Today service areas.
A cartridge replacement service can include removal of the existing PX05MP1, cleaning the accessible filter housing, checking accessible seals, installing the replacement cartridge and checking the system for leaks and normal flow after repressurisation.
Replacement housings, valves, additional cartridges, plumbing repairs and other components are separate where required.
SEDIMENT VS CARBON
PX05MP1 Sediment Cartridge vs CB10MP1 Carbon Cartridge
| Feature |
PX05MP1 |
CB10MP1 |
| Primary Role |
Sediment filtration |
Carbon filtration |
| Media |
Graded polyspun |
Bonded activated carbon block |
| Nominal Rating |
5 micron |
10 micron |
| Cartridge Size |
4.5" × 10" |
4.5" × 10" |
| Main Treatment Role |
Sediment, rust, sand, silt and algae |
Chlorine, unwanted taste, odour and sediment reduction |
| WH2-30 Position |
Stage 1 |
Stage 2 |
COMMON QUESTIONS
Questions About the Puretec PX05MP1
What Is the PX05MP1?
It is a Puretec graded polyspun sediment cartridge in the MaxiPlus 4.5" × 10" format.
What Is Its Micron Rating?
The PX05MP1 has a nominal filtration rating of 5 micron.
What Size Is the Cartridge?
It is a 4.5 inch × 10 inch MaxiPlus cartridge.
What Does the PX05MP1 Remove?
Puretec specifies its PX Series for removal of particulate material including sediment, rust, sand, silt and algae.
Does the PX05MP1 Remove Chlorine?
The PX05MP1 is a sediment cartridge, not a carbon filter. Where chlorine reduction is required, use the applicable carbon filtration stage specified for the system.
What Is the Listed Flow Rate?
Puretec lists the PX05MP1 for flow rates up to 76 litres per minute in applicable system specifications.
Does It Fit a Puretec WH2-30?
Yes. Puretec specifies the PX05MP1 as the first-stage sediment cartridge in the WH2-30 system.
Does It Fit a Puretec WH2-35?
Yes. Puretec's replacement guide also lists the PX05MP1 for the WH2-35.
Will It Fit Every 10-Inch Filter Housing?
No. The PX05MP1 is approximately 4.5 inches in diameter, so compatibility with smaller slimline 10-inch housings should not be assumed.
How Often Should It Be Replaced?
Puretec provides a general whole-house cartridge replacement guide of approximately 6–12 months, depending on water quality and usage.
Can Reduced Water Flow Mean the Cartridge Is Loaded?
Yes. Sediment accumulation can contribute to increased pressure drop and reduced flow, although other plumbing or filtration issues can cause similar symptoms.
Can I Replace It Myself?
Potentially, if the filtration system is designed for user servicing and you can safely isolate, depressurise, open and correctly reseal the housing.
Should I Check the O-Ring During Replacement?
Yes. Puretec recommends checking the filter housing O-ring for damage whenever the housing is opened.
Can Installed Today Replace the Cartridge?
Professional cartridge replacement may be available in eligible service areas where the filtration system is accessible and in serviceable condition.
WHY INSTALLED TODAY
Order Your Puretec PX05MP1 Your Way
Supply Only
Order the genuine Puretec PX05MP1 as a replacement cartridge where you have already confirmed compatibility with your filtration system.
```
Manufacturer-Specified Cartridge
The cartridge uses the Puretec model, size and filtration specification intended for compatible MaxiPlus filtration applications.
Professional Service Option
Professional cartridge replacement may be available in eligible service areas if you would prefer the housing serviced and checked at the same time.
```
FINAL CHECK
Is the Puretec PX05MP1 the Right Cartridge for Your System?
The Puretec PX05MP1 is a genuine 5 micron graded polyspun sediment cartridge designed to capture sediment, rust, sand, silt and algae in compatible filtration systems.
It uses the MaxiPlus 4.5" × 10" format and is listed for flow rates up to 76 L/min. Puretec specifically uses the PX05MP1 as the sediment stage in systems including the WH2-30 and WH2-35.
Before ordering, confirm that your filtration system requires the PX05MP1 model and 4.5" × 10" cartridge format. Replace it according to the applicable maintenance schedule, inspect the housing seal during servicing and check the filtration system for leaks after the new cartridge has been installed.